It also features. Caution The protection provided by the SHDB62M-BW-LL can be impaired if it is used in a manner not described in the user documentation. Find new, used, and rental NI PXIE-4138 PXI Source Measure Unit at Electro Rent. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. The fast sample rate of the PXIe-4141 can reduce measurement times. It seems really easy but I cannot figure out. Due to market conditions delivery times are for general guidance only and may be subject to. Re: PXIe-4163 running voltage sequence occur "Internal Hardware Error". NIが設計するシャーシはこうした要件を上回っており、各スロット. 8 MS/s 100 kS/s Max Update 100 kS/s Max Voltage 10 V 24 V 6 V 8 V 24 V 24 V Max DC Current 100 mA 150 mA 500 mA 3 A 100 mA 50 mA Current Sensitivity 100pA/10pA 100pA/10pA 150pA/15pA 100 fA 10pA/100pA. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. It includes the Digital Pattern Editor for configuring pin maps, specifications, levels, timing, and patterns. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Verifying the System RequirementsPXIe-4112. It has an activity of 4 quadrants with a current resolution of 100 pA and the ability to test up to 100 kS/s. TB-4162 Specifications. 2. 53 GHz Intel Core 2 Duo processor or equivalent. You can pair the PXIe‑7962 with FlexRIO adapter modules that offer high-performance analog and digital I/O. 2. 3. •Current Sesitivity: 10 pA. 5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope. Even when following the above recommendations, combining channels can still present issues with noise, stability, and outputting the proper voltage/current. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. 概要. The DUT is charged to a voltage that does not match the SMU. Adding the. PXI Oscilloscopes. the PXIe-4142. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure UnitIf it is confirmed to be a module issue, follow the steps outlined in DAQ Device or Module Does Not Appear in LabVIEW And/Or MAX. Electro Rent Remains Ready and Available to Support Customers Through COVID-19 Challenges. The PXie Series industrial printers are built to meet the needs of round-the-clock, mission-critical applications. 4 V peak, or 60 VDC. NI-DCPower is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the power supply or SMU and includes examples. PXI Expressの仕様では、各周辺スロットで少なくとも30 Wの電力が利用でき、各スロットで同じ量の熱を放散可能なことを要件としています。. You can also use InstrumentStudio to monitor and control. Issue Details. 8. Find the cable or accessory model name below to see its description. If you have an issue ID, you can search this list to validate that the issue has been fixed. PXIe-4162 PXIe, 12-Channel, ±24 V, 100 pA Precision PXI Source Measure Unit Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. MLS #. The following list details the hardware models supported in NI-DCPower 17. 4162 Gillie Rd, Victoria, BC V9E 2C7 is currently not for sale. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This document explains how to install and use the TB-4162 terminal block with a PXIe-4162. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate. The PXIe-4162 ships with NI-DCPower driver software, which you can use to program the module. Optional Items. Read this document and the documents listed in the additional resources section about. Each * 1+ $797. NET Framework 4. 4. PDF - 785680-01, 785680-02 DXF - 785680-01, 785680-02 3D CAD Models. Industries. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。Model Number(s): PXIe-4162 Product Category: Electrical equipment for measurement, control, and laboratory use. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisNational Instruments PXIe-4135 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. Return to Home Page; Toggle navigation; Solutions. NI-488. The SHDB62M-DB62M-LL is a Low Leakage Cable from National Instruments. Loosen the thumbscrews on the front of the TB-4162 and detach the terminal block from the front of the PXIe-4162. Allow the PXIe-4162/4163 30 minutes to warm up with the PXI chassis fans set to HIGH. Fast Quotes & Shipping. It sounds like it's an NI branded controller and chassis. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog. PXIe-4162; PXIe-4163; Behavior Changes. The rugged, all-metal PXie printers deliver outstanding performance – uppxie-4112は、2つの出力チャンネルを持つ単一象限電源です。両方の出力チャンネル で同じ出力を出すことができます。チャンネルはチャンネル間およびシャーシグラン ド間で絶縁されています。 dc電圧 電圧レンジ 60 v プログラミング可能な最小電圧レベ ル. Brand: National Instruments | Category: Recording Equipment | Size: 0. NI-VISA. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. PXIe, 2. measurements, as well as analog-to. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Verify the accuracy for each configuration in the following table:the PXIe-4162. com. I am interested in using Remote Sense to verify I am supplying the right voltage output. Use extreme caution when a shock hazard is present. 09-09-2018 11:58 PM. Higher power. Terminal Block, TB-4353, PXIe-4353 PXI Temperature Input Module. Caution The protection provided by the SHDB62M-BW-LL can be impaired if it is used in a manner not described in the user documentation. Verifying the System Requirements PXIe-4112. 2 | ni. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. •Current Sesitivity: 100 pA. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. 2. NI‑DCPower 19. 2 For increased capability, NI recommends installing the PXIe-4163 in a chassis with slot cooling. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). National Instruments PXI-8331 User Manual (43 pages) MXI-4 Series Multi-System Extension Interface for PCI, CompactPCI, and PXI Bus Computers. Microsoft Visual Studioのサポート. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will continue to execute, but the Express VI cannot be reconfigured from a dialog box. Refer to the NI website for an up-to-date list of known issues in NI-DCPower 18. 7. NET Class Library, the . PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). The PXIe-4162 ships with NI-DCPower driver software, which you can use to program the module. I'm trying to setup a PXIe-4162 to draw -50 uA from a chip, but regardless of the settings I use, the SMU is sinking -130 uA. 3 PXIe-4162/4163ソースメジャーユニットはサポートされていません。. This cable is designed for use with SMUs (Source Measure Units) such as the PXIe-4162 and PXIe-4163. National Instruments PXIe-4141 Source Measure Unit (SMU) This item is sealed in the manufacturer's static bag. PXIe-4162/PXIe-4163 SMU Open Sense Resistor AccessoryScrew Terminal Block for the PXIe-4162. This is to help prevent the SMU from damaging a DUT if the sense leads do become disconnected. Disconnect or disable all connections to the PXIe-4162/4163. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. Measuring Instruments National Instruments PXIe-4162 Getting Started Manual. Related information: PXIe-4162 Specifications 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 The PXIe-4162 (Part Number: 785680-01) is a unit of estimation of high-density source (SMU)-the device is equipped with 12 SMU channels. 5 mA to 24 mA for I OL and -1. 53 GHz Intel Core 2 Duo processor or equivalent. It also features. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. Industries. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. If I set the PXIe-4162 to draw a higher negative current, say -150 uA, I can measure the current to be exactly -150 uA. Pin View Pane Drive Section; Pin View Pane Active Load Section; niDigital Configure Termination Mode (VI) NI-Digital Pattern Driver Examples. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 5 Known Issues. Make the necessary connections for this procedure, as shown in the following figure:PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisThe PXIe‑6570 is designed for semiconductor characterization and production test. Back to top. a 62 D-sub male to bare wire male low-leakage cable intended for use with PXIe-4162/4163 Source Measure Units. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. 5 digits. Close the NI. Therefore, your maximum frequency will be half of the base clock frequency you are using. Figure 1. OCP is triggered when a fault condition occurs that would otherwise cause the device to sink or source current beyond its specifications for an excessive amount of time. Options. 1 Maximum 480 mA per module. Note Before you begin, install and configure your chassis and controller. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. If I set the PXIe-4162 to draw a higher negative current, say -150 uA, I can measure the current to be exactly -150 uA. Work with our experts to sustain your critical applications. 2 Channels are isolated from earth ground but share a. NI-DCPower 21. Industries. Some functionality described inI try to measure a single channel voltage and current from my PXIe-4162 SMUs. 5 digits. * PXIe-4162/4163ソースメジャーユニットはサポートされていません。 † 独立チャンネルではサポートされていません。 Microsoft Visual StudioのサポートPXIe-4145 PXIe-4147 PXIe-4162 PXIe-4163 驱动. NET Framework 4. Place the module edges into the module guides at the. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. Ensure that the reference signal applied is the. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Contact us with questions for pricing. Pxie, 12-channel, 24 v, 100 ma pxi source measure. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. 2 For increased capability, NI recommends installing the PXIe-4147 in a chassis with slot cooling capacity ≥58 W. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. 4. Wait two minutes for thermal EMF to stabilize. You previously purchased this product. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 8 ms/s isolated digitizer, l and c measurement support, pxi. The following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. 5. This home was built in 2001 and last sold on. We have 3 National Instruments PXIe-4162 manuals available for free PDF download: Getting Started Manual, Manual, User Manual . This file contains important information about InstrumentStudio 2021 Q4, including supported hardware and operating systems, a partial list of bugs fixed, and known issues. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Please contact Artisan Technology Group Sales for configuration pricing and availability. It also features. PXIe-4147. 4 | ni. If you have an issue ID, you can search this list to validate that the issue has been fixed. The following diagram shows a cross-section of the SHDB62M-DB62M-LL when used with a PXIe-4162. Brand: National. Initializing an NI-DCPower session with independent channels allows you to use multiple instruments in the same session. The PXIe-4163 is a high-precision, high-density source measure unit (SMU) with 24 identical SMU channels. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Remove all the modules and try them one at a time, the LED blinking can be related to a module that is failing. Microsoft Visual Studio Support If you are using the NI-DCPower . The PXIe-4162 User Manual provides detailed descriptions of product functionality and step-by-step processes for use. Caution Limit DC power sinking to 12 W. 6: To support independent channels, numerous NI-DCPower functions have been superseded by new versions that can access instrument channels independently. source measure unit (SMU) and includes TB-4162 specifications. This is to help prevent the SMU from damaging a DUT if the sense leads do become disconnected. PXIe-4162 Product Certifications. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. 0 bath property. 6 GHz 8-Core PXI Controller The PXIe‑8862 is an Intel Core i7 8‑Core embedded controller for PXI Express systems. Added support for the PXIe-5110, PXIe-5111, and PXIe-5113 oscilloscopes, newly supported in NI-SCOPE 18. Resistance Specifications Accuracy All resistance accuracy specifications apply to apertures of ≥100 ms, with Offset Compensated Ohms (for ranges ≤10 kΩ) or Auto Zero (for ranges ≥ 100 kΩ) and ADC calibration enabled. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Note Before you begin, install and configure your chassis and controller. Microsoft Visual Studioのサポート. Please refer NI's whitepaper on merging SMU channels. Icons. Table of Contents. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. NI-DCPower 21. pxie-4162是一款高精度、高密度源测量单元(smu),具有12个相同的smu通道。该模块支持四象限运行,每个通道集成远程(4线)感应功能以实现准确测量,并且运用模数转换器技术,帮助您执行高精度测量。Solution. 修理、RMA、キャリブレーション予定. NET Framework 4. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. If you have an issue ID, you can search this list to validate that the issue has been fixed. Table 2. PXIe-4163 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 50 mA 30 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Email: info@artisantg. source measure unit (SMU) and includes TB-4162 specifications. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Installing the TB-4162. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162/4163 SMU 在架构上不同于其他 SMU。. Open a service request. Industries. The capabilities listed in this document represent capabilities available at National Instrument and Certified Calibration Center labs. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Initialize with channel -> configure -> initialize -> measure -> close. The PXIe-4163 is a high-precision, high-density source measure unit. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. The PXIe-4162/4163 SMU differ from other SMUs in architecture. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. The second card was brand new, and after powering up, I did plug into a board. 2. Some functionality described in I try to measure a single channel voltage and current from my PXIe-4162 SMUs. Industries. For example, force 0. Return to Home Page; Toggle navigation; Solutions. This document explains how to install, configure, and test the PXIe-4163. 6. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. A valid service agreement may be required. 3 PXIe-4162/4163ソースメジャーユニットはサポートされていません。. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXI-4110; PXIe-4112; PXIe-4113; PXIe-4154; PXI-4130; PXI-4132; PXIe-4135; PXIe-4136; PXIe-4137;. Once you have found. Calibration could fail for the following reasons: 1. The 2,992 Square Feet single family home is a 5 beds, 3. If you need to configure the current limit for your SMU devices, you can use niDCPower Configure Current Limit VI and niDCPower Configure Current Limit Range VI . The NI SHDB62M-DB62M-LL comes with a shielded, 62-Pin D-Sub male front end connector and an identical back end connector. Use the self-calibration function to reduce errors caused by time and temperature drift. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisFind new, used, and rental NI PXIe-4162 PXIe-4162 12-Channel Precision SMU, 24V 785680-01 at Electro RentMeasuring Instruments National Instruments PXIe-4162 Manual (19 pages) Measuring Instruments National Instruments PXIe-4080 Calibration Procedure. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Buy 786984-01 - Ni - Screw Terminal Connector Kit, PXIe-4162 SMU. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. The PXIe-4147 ships with NI-DCPower driver software, which you can use to program the module. Important Notice: Other accessories, manuals, cables, calibration. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. 5 Current limit set to ≥1 mA and ≥10% of the selected current limit range. Before you begin, install and configure your chassis and controller. This is not an exhaustive list of issues fixed in the. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162 SMU drivers Solved! Go to solution. Allow the PXIe-4162/4163 30 minutes to warm up with the PXI chassis fans set to HIGH. The 416x have a dedicated analog to digital converter per force and sense pin. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. Industries. Issue Details. Specifications are typical at 25 °C unless otherwise noted. Return to Home Page; Toggle navigation; Solutions. NET 4. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Complete the following steps to self-calibrate the PXIe-4162/4163. It features 4-quadrant operation, and each channel has integrated. PXI System Source Measure Units PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • SourceAdapt digital control loop technology • Four-quadrant source and measure capability • High-speed update. It includes 132 single-ended I/O lines configurable as 66 differential pairs. This document explains how to install, configure, and test the PXIe-4162. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。 From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. It may be true, but I don't have enough evidence to back up that claim. NI-DCPower Issue Details I am cascading two or more of NI's Source Measurement Units (SMU) to increase the amount of voltage I can supply. 1. Bug Fixes. pxie, 12 通道, ±24 v, 精密 pxi 源 测量 单元. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. The following diagram shows a cross-section of the SHDB62M-DB62M-LL when used with a PXIe-4162. •Voltage Range: -10 V to 10 V. See all Driver Software Downloads. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 73 lb) typical PXIe-8862 with removable drive 906 g (2. Caution Do not exceed the operating specifications for the module connected to the SHDB62M-BW-LL. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisThe following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. 这减少了类似其他 SMU 在力和感测之间的自动感测电阻器引起的误差. PXIe-4162 DC 電流ソースとシンクレンジ (保証) シャーシスロット冷却能力 ≥58 W 38 W 10 µA 100 µA 1 mA 10 mA 100 mA 60 mA PXIe, 1. 62 MB Table of Contents. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. The SHDB62M-BW-LL features two conductors that are twisted and encapsulated within. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Open a service request. 1 SMU. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high. 82. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Restricted Item . Allow the PXIe-4162/4163 30 minutes to warm up with the PXI chassis fans set to HIGH. 2. Hardware-Timed Sequencing and Triggering. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. It is possible that we stressed some circuits, but I think we did not. 8 PXIe-4162 configured for fast transient response. PXIe-4162/4163 Calibration Accessories Kit. 6. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis PXIe-4162 minimum current sink. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Disconnect or disable all connections to the PXIe-4162/4163. NI Product Documentation Center. Verify the accuracy for each configuration in the following table: the PXIe-4162. 5. National Instruments PXIe-4162 Getting Started Manual (20 pages) PXIe, 12-Channel, 24 V, 100 mA PXI Source Measure Unit. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。The Keysight M9614A is a PXIe 5 channel source / measure unit (SMU). SPECIFICATIONS PXIe-4162 PXIe, 12-Channel, ±24 V, 100 mA Precision PXI Source Measure Unit Definitions Warranted specifications describe the performance of a model. This file contains installation instructions and compatibility information for Instrument Studio 2022 Q3. Industries. Flexible delivery options, including pick-up and delivery, local drop-off. Configuration: •Number of SMU Channels: 24. Return to Home Page; Toggle navigation; Solutions. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. NI‑DCPower 19. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Price may vary with addition of accessories and services. NI InstrumentStudio 2022 Q1 Readme. Close the NI. Technical Documents (1) Technical Data Sheet EN 0 In stock. Caution Do not exceed the operating specifications for the module connected to the SHDB62M-BW-LL. This page provides dimensional drawings for the PXIe-4162. com | PXIe-4162 Specifications PXIe, 12-Channel, ±24 V, 100 mA PXI Source Measure Unit. Measuring Instruments National Instruments PXIe-4162 Manual (19 pages) Measuring Instruments National Instruments PXIe-4080 Calibration Procedure. NI software installs VC2015 Runtime and . You can access the software and documentation known issues list online. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。ground through the shell of the PXIe-4162/4163 front panel connector. It is possible that we stressed some circuits, but I think we did not. Adding the resistor can impact. PXIe-5160/5162 Front Panels CH 0 50Ω: 5 Vpk MAX 1MΩ: 42 Vpk MAX CH 1 TRIG CLK IN PFI 0 OUT 1 NI PXIe-5160 500 MHz Oscilloscope CH 0 50Ω: 5 Vpk MAX 1MΩ: 42 Vpk MAX CH 1 CH 2 CLK IN OUT 1 NI PXIe-5160 500 MHz Oscilloscope CH 3 Note PXIe-5160 shown. •Current Range: -50 mA to 50 mA. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. I'm trying to setup a PXIe-4162 to draw -50 uA from a chip, but regardless of the settings I use, the SMU is sinking -130 uA. 1% of voltage step. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Tektronix is the nation's leading provider of multi-brand calibration services. Also for: Pxie-4082, Pxie-4081. Manufacturer: National Instruments; Model: PXIE; AU Automation Mall ONE USED NI PXIE-4141 781743-01 Source Measure Unit 4 CH Precision SMU module Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods c. 8 MS/s. 3. Brand: National Instruments | Category: Recording Equipment | Size: 0. 2. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Supported Hardware. It helps simplify the task of designing automated test systems for a wide range of applications—from. PXIe-4162 / 785680-01 - NI. GETTING STARTED GUIDE. 10 20 Hz to 20 MHz bandwidth. For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4162 minimum current sink. 0. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Price may vary with addition of accessories and services. The use of the PXIe-416x Open-Sense Protection Accessory or the PXIe-416x Current and Open-Sense Protection Accessory is highly recommended for the 4162 and 4163 SMUs to add the open-sense protection resistor between HI_Force and HI_Sense and between LO_Force and LO_Sense to ensure that the lines are connected. Pxie-4163 Pinout and Leds. The force voltage will reach 25V but other NI SMUs will not show this problem. In addition, numerous NI-DCPower properties can now be configured per channel rather than per session. This page documents all the applicable standards and certifications for the ACC-4162-1 and provides downloadable certifications. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. The PXIe-4163 is a single-slot module with one backplane connector. 概要. The DUT shorts to ground. 3 No support for PXIe-4162/4163 source measure units. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. Current Limit Range VI decides the resolution, while Current Limit VI defines limit. This eliminates the software. It also features. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXIe-4080 measuring instruments pdf manual download. It also features. NETクラスライブラリを使用している場合、. . 2-Channel, 60 V, 1 A PXI Programmable Power Supply. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The TB-4162 terminal block is used for screw terminal connections with the PXIe-4162 SMU. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will continue to execute, but the Express VI. Call the self-calibration function. 1. Work with our experts to sustain your critical applications. A valid service agreement may be required. Contact Us for Immediate Support or Read More. PXIe-4162; PXIe-4163; Behavior Changes.